PARALLAX

intersight_san_connectivity_policy

Manage SAN Connectivity Policies and vHBAs for Cisco Intersight

Collection: cisco.intersight

Full Name: cisco.intersight.intersight_san_connectivity_policy

Synopsis

Manage SAN Connectivity Policies and vHBAs for Cisco Intersight

Parameters

NameTypeRequiredDefaultDescription
api_private_keystringFilename (absolute path) or string of PEM formatted private key data to be used for Intersight API authentication. If a string is used, Ansible vault should be used to encrypt string data. Ex. ansible-vault encrypt_string –vault-id tme@/Users/dsoper/Documents/vault_password_file ‘—–BEGIN EC PRIVATE KEY—– —–END EC PRIVATE KEY—–’ If not set, the value of the INTERSIGHT_API_PRIVATE_KEY environment variable is used. Required if I(api_bearer_token) is not provided. Secret value; omitted from logs and results.
api_uristringhttps://intersight.com/api/v1URI used to access the Intersight API. If not set, the value of the INTERSIGHT_API_URI environment variable is used.
api_key_idstringPublic API Key ID associated with the private key. If not set, the value of the INTERSIGHT_API_KEY_ID environment variable is used. Required if I(api_bearer_token) is not provided.
api_bearer_tokenstringBearer token for OAuth2 authentication with the Intersight API. When provided, I(api_key_id) and I(api_private_key) are not required and the C(cryptography) Python library is not needed. If not set, the value of the INTERSIGHT_API_BEARER_TOKEN environment variable is used. Secret value; omitted from logs and results.
validate_certsbooltrueBoolean control for verifying the api_uri TLS certificate
use_proxybooltrueIf C(no), it will not use a proxy, even if one is defined in an environment variable on the target hosts.
statestringpresentIf C(present), will verify the resource is present and will create if needed. If C(absent), will verify the resource is absent and will delete if needed. Choices: present, absent
organizationstringdefaultThe name of the Organization this resource is assigned to. Policies created within a Custom Organization are applicable only to devices in the same Organization. Use ‘default’ for the default organization.
namestringyesThe name assigned to the SAN Connectivity Policy. Must be unique within the organization. The name must be between 1 and 64 alphanumeric characters, allowing special characters :-_.
descriptionstringThe user-defined description for the SAN Connectivity Policy. Description can contain letters(a-z, A-Z), numbers(0-9), hyphen(-), period(.), colon(:), or an underscore(_).
tagslistList of tags in Key: Value: format.
target_platformstringStandaloneThe platform type for which the SAN Connectivity policy is intended. C(Standalone) for Standalone servers. C(FIAttached) for fabric interconnect attached servers. Note SAN Connectivity policies are not supported on unified edge servers. Choices: Standalone, FIAttached
placement_modestringcustomThe mode used for placement of vHBAs on network adapters. C(custom) requires manual placement specification for each vHBA. C(auto) automatically distributes vHBAs between adapters during profile deployment. Only applicable for FIAttached target platform. Choices: custom, auto
wwnn_address_typestringpoolType of WWNN address assignment. C(pool) to use a WWNN pool. C(static) to manually assign a static WWNN address. Only applicable when target_platform is FIAttached. Choices: pool, static
wwnn_poolstringThe WWNN pool that is assigned for WWNN address assignment. Required when wwnn_address_type is pool and target platform is FIAttached. Only applicable for FIAttached target platform.
static_wwnn_addressstringThe WWNN address for the server node must be in hexadecimal format xx:xx:xx:xx:xx:xx:xx:xx. Allowed ranges are 20:00:00:00:00:00:00:00 to 20:FF:FF:FF:FF:FF:FF:FF or from 50:00:00:00:00:00:00:00 to 5F:FF:FF:FF:FF:FF:FF:FF. To ensure uniqueness of WWN’s in the SAN fabric, you are strongly encouraged to use the WWN prefix - 20:00:00:25:B5:xx:xx:xx. Required when wwnn_address_type is static and target platform is FIAttached. Only applicable for FIAttached target platform.
vhbaslistList of vHBAs to be created and attached to the SAN Connectivity policy. Each vHBA will be configured with the specified fibre channel policies. Configuration options vary based on target_platform. Nested options: name (str) required; state (str) default=present; vhba_type (str); slot_id (str); pci_link (int) default=0; uplink_port (int) default=0; pci_order (int) default=0; persistent_lun_bindings (bool) default=false; fibre_channel_network_policy (str); fibre_channel_qos_policy (str); fibre_channel_adapter_policy (str); pin_group_name (str); wwpn_address_type (str) default=pool; wwpn_pool (str); static_wwpn_address (str); switch_id (str) default=a; auto_slot_id (bool) default=true; auto_pci_link (bool) default=true; pci_link_assignment_mode (str); fibre_channel_zone_policies (list)

Example

yaml
- cisco.intersight.intersight_san_connectivity_policy:
    api_key_id: '{{ api_key_id }}'
    api_private_key: '{{ api_private_key }}'
    description: SAN connectivity policy for standalone servers
    name: standalone-san-policy
    organization: default
    state: present
    tags:
        - Key: Environment
          Value: Production
        - Key: Site
          Value: DataCenter-A
    target_platform: Standalone
    vhbas:
        - fibre_channel_adapter_policy: fc-adapter-policy
          fibre_channel_network_policy: fc-network-policy
          fibre_channel_qos_policy: fc-qos-policy
          name: vhba0
          pci_link: 0
          pci_order: 0
          persistent_lun_bindings: false
          slot_id: "1"
          uplink_port: 0
          vhba_type: fc-initiator
        - fibre_channel_adapter_policy: fc-adapter-policy
          fibre_channel_network_policy: fc-network-policy
          fibre_channel_qos_policy: fc-qos-policy
          name: vhba1
          pci_link: 0
          pci_order: 5
          persistent_lun_bindings: true
          slot_id: "4"
          uplink_port: 2
          vhba_type: fc-nvme-initiator
  name: Create a SAN Connectivity Policy for Standalone servers

- cisco.intersight.intersight_san_connectivity_policy:
    api_key_id: '{{ api_key_id }}'
    api_private_key: '{{ api_private_key }}'
    description: SAN policy with automatic vHBA placement
    name: auto-placement-san-policy
    organization: default
    placement_mode: auto
    state: present
    target_platform: FIAttached
    vhbas:
        - fibre_channel_adapter_policy: fc-adapter-policy
          fibre_channel_network_policy: fc-network-policy
          fibre_channel_qos_policy: fc-qos-policy
          name: vhba-auto-1
          switch_id: a
          vhba_type: fc-initiator
          wwpn_address_type: pool
          wwpn_pool: default-wwpn-pool
        - fibre_channel_adapter_policy: fc-adapter-policy
          fibre_channel_network_policy: fc-network-policy
          fibre_channel_qos_policy: fc-qos-policy
          name: vhba-auto-2
          switch_id: b
          vhba_type: fc-initiator
          wwpn_address_type: pool
          wwpn_pool: default-wwpn-pool
    wwnn_address_type: pool
    wwnn_pool: default-wwnn-pool
  name: Create a SAN Connectivity Policy with auto placement

- cisco.intersight.intersight_san_connectivity_policy:
    api_key_id: '{{ api_key_id }}'
    api_private_key: '{{ api_private_key }}'
    description: SAN connectivity policy for FI-attached servers
    name: fi-attached-san-policy
    organization: default
    placement_mode: custom
    state: present
    tags:
        - Key: Environment
          Value: Production
    target_platform: FIAttached
    vhbas:
        - auto_pci_link: true
          auto_slot_id: true
          fibre_channel_adapter_policy: fc-adapter-policy
          fibre_channel_network_policy: fc-network-policy
          fibre_channel_qos_policy: fc-qos-policy
          fibre_channel_zone_policies:
            - fc-zone-policy-1
          name: vhba-a
          pci_order: 0
          persistent_lun_bindings: false
          switch_id: a
          vhba_type: fc-initiator
          wwpn_address_type: pool
          wwpn_pool: default-wwpn-pool
        - auto_pci_link: true
          auto_slot_id: true
          fibre_channel_adapter_policy: fc-adapter-policy
          fibre_channel_network_policy: fc-network-policy
          fibre_channel_qos_policy: fc-qos-policy
          fibre_channel_zone_policies:
            - fc-zone-policy-1
          name: vhba-b
          pci_order: 1
          persistent_lun_bindings: false
          switch_id: b
          vhba_type: fc-initiator
          wwpn_address_type: pool
          wwpn_pool: default-wwpn-pool
    wwnn_address_type: pool
    wwnn_pool: default-wwnn-pool
  name: Create a SAN Connectivity Policy for FI-Attached servers with WWNN pool

- cisco.intersight.intersight_san_connectivity_policy:
    api_key_id: '{{ api_key_id }}'
    api_private_key: '{{ api_private_key }}'
    description: SAN connectivity policy with static addresses
    name: fi-attached-static-san-policy
    organization: default
    placement_mode: custom
    state: present
    target_platform: FIAttached
    vhbas:
        - auto_pci_link: false
          auto_slot_id: false
          fibre_channel_adapter_policy: fc-adapter-policy
          fibre_channel_network_policy: fc-network-policy
          fibre_channel_qos_policy: fc-qos-policy
          fibre_channel_zone_policies:
            - fc-zone-policy-1
          name: vhba-static
          pci_link_assignment_mode: load-balanced
          pci_order: 1
          persistent_lun_bindings: true
          slot_id: "2"
          static_wwpn_address: "50:00:00:00:00:00:00:00"
          switch_id: b
          vhba_type: fc-target
          wwpn_address_type: static
    wwnn_address_type: pool
    wwnn_pool: default-wwnn-pool
  name: Create a SAN Connectivity Policy for FI-Attached with static WWPN

- cisco.intersight.intersight_san_connectivity_policy:
    api_key_id: '{{ api_key_id }}'
    api_private_key: '{{ api_private_key }}'
    description: SAN connectivity with custom placement
    name: fi-attached-advanced-placement
    organization: default
    placement_mode: custom
    state: present
    static_wwnn_address: 20:00:00:25:B5:00:00:01
    target_platform: FIAttached
    vhbas:
        - auto_pci_link: false
          auto_slot_id: false
          fibre_channel_adapter_policy: fc-adapter-policy
          fibre_channel_network_policy: fc-network-policy
          fibre_channel_qos_policy: fc-qos-policy
          name: vhba-custom
          pci_link: 1
          pci_link_assignment_mode: custom
          pci_order: 3
          persistent_lun_bindings: false
          pin_group_name: pingroup-a
          slot_id: MLOM
          switch_id: a
          vhba_type: fc-initiator
          wwpn_address_type: pool
          wwpn_pool: wwpn-pool
    wwnn_address_type: static
  name: Create a SAN Connectivity Policy for FI-Attached with advanced placement

- cisco.intersight.intersight_san_connectivity_policy:
    api_key_id: '{{ api_key_id }}'
    api_private_key: '{{ api_private_key }}'
    description: Policy demonstrating vHBA state management
    name: mixed-vhba-states-policy
    organization: default
    state: present
    target_platform: Standalone
    vhbas:
        - fibre_channel_adapter_policy: fc-adapter-policy
          fibre_channel_network_policy: fc-network-policy
          fibre_channel_qos_policy: fc-qos-policy
          name: vhba0
          pci_link: 0
          pci_order: 0
          persistent_lun_bindings: false
          slot_id: "1"
          state: present
          uplink_port: 0
          vhba_type: fc-initiator
        - name: vhba-old
          state: absent
        - fibre_channel_adapter_policy: fc-adapter-policy
          fibre_channel_network_policy: fc-network-policy
          fibre_channel_qos_policy: fc-qos-policy
          name: vhba-new
          pci_link: 0
          pci_order: 1
          persistent_lun_bindings: true
          slot_id: "3"
          state: present
          uplink_port: 1
          vhba_type: fc-nvme-initiator
  name: Update SAN connectivity policy - manage vHBA states

- cisco.intersight.intersight_san_connectivity_policy:
    api_key_id: '{{ api_key_id }}'
    api_private_key: '{{ api_private_key }}'
    name: old-san-policy
    state: absent
  name: Delete a SAN Connectivity Policy