PARALLAX

intersight_power_policy

Power Policy configuration for Cisco Intersight

Collection: cisco.intersight

Full Name: cisco.intersight.intersight_power_policy

Synopsis

Power Policy configuration for Cisco Intersight

Parameters

NameTypeRequiredDefaultDescription
api_private_keystringFilename (absolute path) or string of PEM formatted private key data to be used for Intersight API authentication. If a string is used, Ansible vault should be used to encrypt string data. Ex. ansible-vault encrypt_string –vault-id tme@/Users/dsoper/Documents/vault_password_file ‘—–BEGIN EC PRIVATE KEY—– —–END EC PRIVATE KEY—–’ If not set, the value of the INTERSIGHT_API_PRIVATE_KEY environment variable is used. Required if I(api_bearer_token) is not provided. Secret value; omitted from logs and results.
api_uristringhttps://intersight.com/api/v1URI used to access the Intersight API. If not set, the value of the INTERSIGHT_API_URI environment variable is used.
api_key_idstringPublic API Key ID associated with the private key. If not set, the value of the INTERSIGHT_API_KEY_ID environment variable is used. Required if I(api_bearer_token) is not provided.
api_bearer_tokenstringBearer token for OAuth2 authentication with the Intersight API. When provided, I(api_key_id) and I(api_private_key) are not required and the C(cryptography) Python library is not needed. If not set, the value of the INTERSIGHT_API_BEARER_TOKEN environment variable is used. Secret value; omitted from logs and results.
validate_certsbooltrueBoolean control for verifying the api_uri TLS certificate
use_proxybooltrueIf C(no), it will not use a proxy, even if one is defined in an environment variable on the target hosts.
statestringpresentIf C(present), will verify the resource is present and will create if needed. If C(absent), will verify the resource is absent and will delete if needed. Choices: present, absent
organizationstringdefaultThe name of the Organization this resource is assigned to. Profiles, Policies, and Pools that are created within a Custom Organization are applicable only to devices in the same Organization.
namestringyesThe name assigned to the Power Policy. The name must be between 1 and 64 alphanumeric characters, allowing special characters :-_.
descriptionstringThe user-defined description for the Power Policy. Description can contain letters(a-z, A-Z), numbers(0-9), hyphen(-), period(.), colon(:), or an underscore(_).
tagslistList of tags in Key: Value: format.
target_platformstringThe platform type for which the power policy is intended. This determines which settings are applicable. This parameter is required when C(state) is C(present). Choices: All, Standalone, FIAttached, Chassis
power_profilingstringEnabledSets the Power Profiling of the Server. If Enabled, this field allows the power manager to run power profiling utility to determine the power needs of the server. This field is only supported for Cisco UCS X series servers. Applicable for ‘FIAttached’ and ‘All’ platforms. Choices: Enabled, Disabled
power_prioritystringLowSets the Power Priority of the Server. This priority is used to determine the initial power allocation for servers. This field is only supported for Cisco UCS B series and X series servers. Applicable for ‘FIAttached’ and ‘All’ platforms. Choices: Low, Medium, High
power_restorestringAlwaysOffSets the Power Restore State of the Server. In the absence of Intersight connectivity, the chassis/server will use this policy to recover the host power after a power loss event. Applicable for ‘Standalone’, ‘FIAttached’, and ‘All’ platforms. Choices: AlwaysOff, AlwaysOn, LastState
power_redundancystringGridSets the Power Redundancy Mode of the Chassis. Redundancy Mode determines the number of PSUs the chassis keeps as redundant. N+2 mode is only supported for Cisco UCS X series Chassis. Applicable for ‘Chassis’ and ‘All’ platforms. Choices: Grid, NotRedundant, N+1, N+2
processor_package_power_limitstringDefaultSets the Processor Package Power Limit (PPL) of a server. PPL refers to the amount of power that a CPU can draw from the power supply. The Processor Package Power Limit (PPL) feature is currently available exclusively on Cisco UCS C225/C245 M8 servers. Applicable for ‘Standalone’, ‘FIAttached’, and ‘All’ platforms. Choices: Default, Maximum, Minimum
power_save_modestringEnabledSets the power save mode of the chassis. If the requested power budget is less than available power capacity, the additional PSUs not required to comply with redundancy policy are placed in power save mode. Applicable for ‘Chassis’ and ‘All’ platforms. Choices: Enabled, Disabled
dynamic_power_rebalancingstringEnabledSets the dynamic power rebalancing mode of the chassis. If enabled, this mode allows the chassis to dynamically reallocate the power between servers depending on their power usage. Applicable for ‘Chassis’ and ‘All’ platforms. Choices: Enabled, Disabled
extended_power_capacitystringEnabledSets the Extended Power Capacity of the Chassis. If Enabled, this mode allows chassis available power to be increased by borrowing power from redundant power supplies. This option is only supported for Cisco UCS X series Chassis. Applicable for ‘Chassis’ and ‘All’ platforms. Choices: Enabled, Disabled
power_allocationint0Sets the limit for the maximum input power consumption by the chassis (in Watts). Set to 0 for no limit. Applicable for ‘Chassis’ and ‘All’ platforms.

Example

yaml
- cisco.intersight.intersight_power_policy:
    api_key_id: '{{ api_key_id }}'
    api_private_key: '{{ api_private_key }}'
    description: Power policy for standalone servers, restores to last state.
    name: Standalone-Server-Power-Policy
    power_restore: LastState
    processor_package_power_limit: Minimum
    tags:
        - Key: Owner
          Value: DevOps
    target_platform: Standalone
  name: Create a Power Policy for a Standalone Server

- cisco.intersight.intersight_power_policy:
    api_key_id: '{{ api_key_id }}'
    api_private_key: '{{ api_private_key }}'
    description: Power policy for chassis with N+1 redundancy.
    name: Chassis-N1-Redundancy
    power_allocation: 7500
    power_redundancy: N+1
    power_save_mode: Disabled
    target_platform: Chassis
  name: Create a Power Policy for a Chassis with N+1 Redundancy

- cisco.intersight.intersight_power_policy:
    api_key_id: '{{ api_key_id }}'
    api_private_key: '{{ api_private_key }}'
    description: Default power policy for all FIAttached servers.
    name: FI-Attached-Default
    power_priority: Medium
    power_profiling: Enabled
    target_platform: FIAttached
  name: Create a universal Power Policy for FIAttached Servers

- cisco.intersight.intersight_power_policy:
    api_key_id: '{{ api_key_id }}'
    api_private_key: '{{ api_private_key }}'
    name: Standalone-Server-Power-Policy
    state: absent
  name: Delete a Power Policy